Ubiquiti (EAH-8) Ubiquiti Enterprise Access Hub, With Entry And Exit Control to Eight Doors, Battery Backup Support,(8) Lock terminals (12V or Dry), 2Yr Warr

Write a Review
SKU:
EAH-8
MPN:
EAH8
Availability:
Not available
Shipping:
Calculated at Checkout
  • Ubiquiti (EAH-8) Ubiquiti Enterprise Access Hub, With Entry And Exit Control to Eight Doors, Battery Backup Support,(8) Lock terminals (12V or Dry), 2Yr Warr
  • Ubiquiti (EAH-8) Ubiquiti Enterprise Access Hub, With Entry And Exit Control to Eight Doors, Battery Backup Support,(8) Lock terminals (12V or Dry), 2Yr Warr
  • Ubiquiti (EAH-8) Ubiquiti Enterprise Access Hub, With Entry And Exit Control to Eight Doors, Battery Backup Support,(8) Lock terminals (12V or Dry), 2Yr Warr
  • Ubiquiti (EAH-8) Ubiquiti Enterprise Access Hub, With Entry And Exit Control to Eight Doors, Battery Backup Support,(8) Lock terminals (12V or Dry), 2Yr Warr
MSRP: $2,209.90
$2,032.97
Inc. GST
MSRP: $2,009.00
$1,848.15
Ex. GST
— You save $176.93

Frequently bought together:

Description

Product Description

Enterprise-grade access hub with entry and exit control up to eight doors and battery backup support.

lock (8) Lock terminals (12V or Dry)

doors (8+8) Inputs for request-to-exit devices and door position sensors

rj45_port (8) PoE ports for Access Readers

alarm (4) AUX terminals for chimes, sirens, or door openers

battery_full (1) Battery backup input (32-48V)

Technical Details

Mechanical
Dimensions 379 x 355 x 105 mm (15 x 14 x 4.1")
Weight Device: 9.1 kg (20 lb) Mount: 624 g (1.4 lb)
Enclosure material SGCC housing with PC cover
Mounting material SGCC wall mount plate
Hardware
Networking interface (10) 10/100/1000 Base-T
Power method Universal input, 100-240V AC, Max. 4.4A, 50/60Hz 32-48V DC Lead Acid Battery, Max. 7.5A @32V
Power supply AC/DC, internal
Max. power consumption 240W
PoE interface (8) PoE (Pins 1, 2+; 3, 6-)
Voltage range PoE mode 44-57V DC
Total available PoE 60W
Max. PoE wattage per port 15.4W
LEDs System: white/blue Output relays: steady white Ethernet: flashing white
Button (1) Factory-reset
Digital input (8) Inputs for request-to-exit devices (8) Inputs for door position sensors (1) Emergency
Dry output relay (8) Lock terminals (12V or Dry) (4) AUX terminals for advanced setup (Chime/Siren/Door opener)
Powered output relay Lock: 12V DC, 1A/ Dry Aux: Dry only
Recommend max. cable length
18 AWG UACC-Cable-DoorLockRelay length 20 AWG length 22 AWG length 24 AWG length
UA-Lock-Electric (400mA) 100 m (328 ft) 66 m (217 ft) 42 m (138 ft) 25 m (82 ft)
UA-Lock-Magnetic-270kg (800mA) 46 m (151 ft) 30 m (98 ft) 20 m (66 ft) 12 m (29 ft)
UA-Lock-Magnetic-540kg (500mA) 80 m (262 ft) 51 m (167 ft) 32 m (105 ft) 20 m (66 ft)
Other locks (1A) 36 m (118 ft) 24 m (79 ft) 15 m (49 ft) 9 m (30 ft)
Operating environment Indoor use only
Ambient operating temperature 0 to 40° C (32 to 104° F)
Ambient operating humidity 5 to 95% noncondensing
Software information The software version of a product can be checked at https://unifi.ui.com
UL 294 level Destructive attack: Level I Line security: Level I Endurance: Level I Standby power: Level I
UL 294 statement Compliance with IEEE 802.3 specifications was not verified as part of UL 294. The equipment is intended to comply with the section of the National Electrical Code, ANSI/NFPA 70, Article 725.121, Power Sources for Class 2 and Class 3 Circuits.
PoE cabling requirements Cable 5e cabling is the minimum performance category recommended. The performance category utilized should match the transmission speed required at the installation site. The minimal conductor gauge permitted to connect between the PSE or power injector and the PD shall be 26 AWG (0.13 mm 2 ) for patch cords; 24 AWG (0.21 mm 2 ) for horizontal or riser cable.
CAN/ULC-60839-11-1 Grade Grade assignment: I
Certifications CE, FCC, IC, UL 294, CAN/ULC-60839-11-1
Document number, and issue date and/or revision level EAH-8, Ver 01
LED
System Steady blue: adopted, device is ready Steady white: pending adoption Blinking white/blue: upgrading firmware Breathing white: system initiating
Software
Management application UniFi Access: Version 1.22.17 and later

Product Details

Enterprise Access Hub

Enterprise Access Hub

Deplyment

Deployment

In the Box

In the Box

Build Features

Build Features

Installation Guide

View AllClose